Logbook of meteorological data collected 9/18/2007 'Created by author: Mandana Farhadieh' Set up location: Scripps facility at Torrey pines Rd. Sensors used: LI200X Pyranometer, CS215Temprature and Humidity Probe, Standard Anemometer, and the solar panel,T107 temprature probe. Each mounted on the 10 ft tripod and connected to the CR1000 datalogger and the PS100 12V rechargeable power supply, placed in the ENC12/14 in order to be protected from the sun light. Goal: Get a series of data for the sensors mounted at a different location compared to the CMRR station Cup anemometer wasn’t working properly in the begining due to the miswiring so unfortunately got all zeros for wind speed. wind offset was 60.91 degrees of (C) Set up spot was perfect with no buildings blocking so Pyranometer data should be almost accurate for solar radiation measurements. The temperature humidity probe and T107 worked just fine and we got reasonable data from it based on the time of the day we were doing the experiment. datalogger program was working perfectly. 11:40 on 9/11/2007 Start of our measurement after making some changes for the wiring and we left the set up outside. 10:05 on 9/18/2007 End of the data file and measurement downloaded from data logger on 9/18/07.