Kearny Mesa High School ROOFTOP STATION CR1000 s/n 15591 INSTRUMENT HEIGHT S/N SHT75 160 5 Pyranometer 215 58059 Tn9 150 1 Davis Rain Davis Wind 190 UV sensor 220 reading of 275 = winds from 110 degrees Sep 2008 Installation 11/12/2008 AJD, SN 1300-1630h PST, clear station had fallen over, Weighted down station with cinder blocks Ran cable from roof to classroom Updated program, got all sensors working 12/3/2008 AJD, 1300-1630h PST, partly cloudy -reading of 275 = winds from 110 degrees -station fully operational, they need loggernet to connect via IP For Next Time: -bring extra TN9 (existing may not be working) -run new ethernet cable to new classroom (left box with cable there) -measure building height -bring thermistors, epoxy, duct tape, connectors, etc. if SP temp reading is desired -take photos