'CR1000 Public Solar_Radiation, Batt_Volt Public Li200Cal100Ohm Const Li200Cal = -11.12 'Calibration constant for Licor 200X Solar Pyranometer W/m2 / uA Units Solar_Radiation = W/m^2 Units Batt_Volt = V Units Li200Cal100Ohm = W/m2 / mW 'Define Data Tables DataTable(Main,True,-1) DataInterval(0,1,Sec,10) Sample(1,Solar_Radiation,FP2) EndTable 'Main Program BeginProg ' calculate instruction for mV measurement across 100 Ohm resistor Li200Cal100Ohm = Li200Cal * 10 Scan(1,Sec,0,0) 'Default Datalogger Battery Voltage measurement Batt_Volt: Battery(Batt_Volt) 'LI200X Pyranometer measurement SlrW: VoltDiff(Solar_Radiation,1,mV25,1,True,0,_60Hz,Li200Cal100Ohm,0) CallTable(Main) NextScan EndProg 'wiring instructions 'Li200SZ Pyranometer ' clear with copper wire: 1H ' silver: 1L ' 100 Ohm resistor from 1H to 1L